Comment fonctionne un dépoussiéreur à impulsion

Comment les vannes à impulsion, réservoirs, séquenceurs et l'air comprimé nettoient ensemble les filtres à manches et à cartouches.

Pulse valves, header tanks, controllers and compressed air work together to clean the filters of baghouse and cartridge dust collectors while the installation stays online.

The cleaning cycle

Dust-laden air passes through the filter media and leaves a dust cake on the outside. As the cake builds up, differential pressure rises and airflow drops. A controller fires a pilot valve, which opens a diaphragm pulse valve on the header tank. The tank releases a short burst of compressed air into the blow tube, the shock wave flexes the media, and the dust cake falls into the hopper.

What determines cleaning performance

  • Header tank volume and pressure at the valve
  • Valve size and orifice matched to the blow tube
  • Pulse duration and interval set on the controller
  • Diaphragm condition and the correct repair kit
  • Dry, oil-free compressed air

Related pages

VDC Group, Verhoeven Dust Control

+32 78 700 178

info@vdcgroup.be